2019 Fatality #20 / Coal #10

On September 17, 2019, an electrician was electrocuted when he contacted an energized conductor. The victim contacted a 995 VAC connector while attempting to troubleshoot the scrubber motor circuit on a continuous mining machine.

Best Practices: 

  • Lock out and tag out the electrical circuit yourself. Never rely on others to do this for you.
  • BEFORE performing electrical work:
    • Open the circuit breaker or load break switch away from the enclosure to de-energize the incoming power cables or conductors.
    • Open the visual disconnect away from the enclosure to confirm that the incoming power cables or conductors have been de-energized.
    • Lock out and tag out the visual disconnect.
    • Ground the de-energized phase conductors.
  • Wear properly rated and well maintained electrical gloves when troubleshooting or testing energized circuits.  After the electrical problem has been found, follow the proper steps before performing electrical work.
  • Use properly rated electrical meters and non-contact voltage testers to ensure electrical circuits have been de-energized.
  • Only use qualified, trained workers. Ensure electrical work is performed by a qualified electrician or someone trained to do electrical work under a qualified electrician’s direct supervision.
  • Identify circuits and circuit breakers. Properly identify all electrical circuits and circuit breakers before troubleshooting or performing electrical work.

Click here for: MSHA Preliminary Report (pdf), Final Report (pdf).