Coal Fatality – 9/1/22

On September 1, 2022, a roof bolter was electrocuted when he contacted a metal hook that became energized after it penetrated the 480-volt cable that supplied electrical power to a roof bolting machine.

Best Practices: 

  • Make sure miners use suitable, non-conductive ropes when pulling or handling electrical cables. 
  • Never attach conductive parts, such as metallic hooks, to the portions of non-conductive ropes that contact electrical cables.
  • Make sure miners use proper Personal Protective Equipment when handling cables, such as insulated gloves.

Additional Information: 

This is the 20th fatality reported in 2022, and the first classified as “Electrical.”

Click here for: Preliminary Report (pdf), Final Report (pdf).